SIPLUS LOGO! 230RCE -20 … +70 °C Start up -20 °C With conformal coating Based on 6ED1052-1FB08-0BA0 . Logic module, display PS/I/O: 115 V/230 V/relay, 8 DI (4 AI)/4 DQ, memory 400 blocks, modularly expandable, Ethernet Integr. web server, data log, user-defined web pages, standard microSD card For LOGO! Soft Comfort V8 or higher, older projects executable
SIPLUS LOGO!
Overview
- The controller for use in the toughest ambient conditions
- With extended temperature range from -40/-25 °C to +70 °C
- Suitable for exposure to environmental substances (harmful gas atmosphere)
- Condensation permissible
- With the proven PLC technology of LOGO!
- Easy to handle, program, maintain, and service
- Ideal for use in automotive engineering, environmental engineering, mining, chemical plants, conveyor technology, food industry, etc.
Accessories:
- The front panel mounting kit also allows simple and reliable installation of the logic modules in front panels; degree of protection IP65 is thus possible.
- In order to ensure dependable operation of devices supplied by the battery in conjunction with combustion engines, it is necessary to put in a SIPLUS upmiter upstream device between the battery and the SIPLUS LOGO!.
Technical specifications
General technical specifications of the SIPLUS LOGO! | |
Range of ambient temperature | -40/-25 … +70 °C |
Conformal coating | Coating of the printed-circuit boards and the electronic components |
Technical specifications | The technical data of the standardSản phẩm applies except for the ambient conditions. |
Ambient conditions | |
Extended range of ambient conditions | |
| Tmin … Tmax at 1080 hPa … 795 hPa (-1000 m … +2000 m) // |
| 0 °C |
Relative humidity | |
| 100%; RH incl. condensation/frost (no commissioning in bedewed state) |
Resistance | |
| Yes; Class 3B2 mold and fungal spores (except fauna); the supplied plug covers must remain in place on the unused interfaces during operation. |
| Yes; Class 3C4 (RH < 75%) incl. salt spray in accordance with EN 60068-2-52 (severity 3); the supplied plug covers must remain in place on the unused interfaces during operation. |
| Yes; Class 3S4 incl. sand, dust; the supplied plug covers must remain in place on unused interfaces during operation. |
Liên hệ:
Để được tư vấn trực tiếp, Quý khách chỉ cần gọi số Hotline của chúng tôi theo thông tin sau:
➢ Tư vấn bán hàng: 0988 568 790 (Call/Zalo)
➢ Email: bvtech790@gmail.com - info@bvtech.tech
Hoặc chat để trò chuyện trực tiếp với chuyên viên tư vấn bên góc phải màn hình của bạn
Cảm ơn quý khách đã truy cập vào website bvtech.tech. Kính chúc quý khách nhận được những thông tin hữu ích và có những trải nghiệm tuyệt vời trên trang.
Đánh giá
Chưa có đánh giá nào.